Properly organized ventilation in the apartment is the basis of a comfortable microclimate in the living room. Very often, natural air exchange does not provide a sufficient supply of fresh air and one has to look for alternative ways to improve the supply ventilation.
We will tell you all about the existing options for organizing air exchange, help you choose the best method. The presented article describes in detail the simplest versions of devices for improving ventilation and complex technical systems. Based on our recommendations, you will significantly improve your living conditions.
Air exchange is the key to a healthy microclimate
For normal operation of the apartment, a single air exchange per hour is sufficient. The implementation of this norm is ensured by laying ventilation ducts of natural extraction.
The intake of fresh air during unorganized air exchange is carried out through leaks of window frames, slotted openings in door structures, window leaves and vapor-permeable wall material.
After installing sealed double-glazed windows, the ventilation scheme fails - the channel for supplying air to the apartment is blocked, the pressure difference is reduced and the exhaust fumes stagnate in the room.
Scheme of natural circulation: 1 - air flow through the slots of the window frames, 2 - movement of the air flow through the gaps of the threshold, 3 - removal of exhaust air through ventilation ducts. Natural circulation is based on the difference in temperature and pressure inside and outside the building
Many apartment residents are faced with negative factors that indicate problems with the ventilation system:
- Deterioration in air quality. At home, there is a lack of oxygen, due to an excess of carbon dioxide, the air becomes stale. A “heavy” atmosphere causes discomfort, headaches and fatigue.
- Stagnation of unpleasant odors. In a “canned” apartment, the aromas accompanying a person’s life are kept for a long time. Exhaust appliances in the kitchen or in the bathroom cease to function fully.
- High humidity. A clear sign of the problem is condensation on the windows and wet corners on the walls. Subsequently, black dots - the first manifestations of mold - can be found on surfaces. In such conditions, the decoration of the room is saturated with moisture and is gradually destroyed.
If time does not take care of unhindered and regular supply of street air, then the likelihood of allergic and viral diseases increases.
A non-renewable musty atmosphere stimulates the development of pathogenic fungi, parasite mites and bacteria. Elderly people and young children react very quickly to air deterioration.
Restoring the intensity of air flow solves these problems.
Regardless of the chosen method of organizing the supply ventilation, it is necessary to provide the following air exchange standards based on one living:
- a bedroom, a children's room and a living room - 30 m3 / h;
- kitchen - 60-90 cubic meters / h;
- Bathroom - 25-50 cubic meters / h.
Air intake requirements for a kitchen depend on the type of stove installed. The exact standards for the bathroom are determined on the basis of the joint or separate use of the toilet and the bathroom.
The parameters are relevant if the maximum concentration of harmful components in the atmosphere does not exceed the established standard indicators for settlements
If the premises are not operated for permanent housing, then the minimum air exchange rate for residential and non-residential rooms is reduced by 0.2 h-1 and 0.5 h-1, respectively.
Image Gallery
Photo from
Supply ventilation in the apartment
Miniature wall unit
Air conditioning with outdoor air intake
Channelless ventilation device
The simplest wall supply valve
Recirculation channel option
Volatile Supply Unit
Self-made air outflow through openings
Full information about the calculations for the device and the modernization of ventilation is given in this article. We recommend that you familiarize yourself with useful information.
Ways to increase the efficiency of air in
Various methods aimed at improving the efficiency of supply ventilation are divided into two main categories:
- measures that increase air flow without pressure devices;
- use of forced air systems.
The first group includes: manual or automatic ventilation, installation of a window or wall valve.
Manual ventilation. Opening the window for 15 minutes with a frequency of 3 hours. It is almost impossible to put the method into practice - there is no time or no one to constantly open and close the window. An alternative is to open the sash in micro-ventilation mode.
The disadvantage of this method is that dust from the street and noise penetrate the apartment through a gap in the apartment. In winter, with micro-ventilation, the room gradually cools.
Automatic airing. A servo drive is installed on the window flap. The device is programmed to open the transom at specified intervals or is equipped with a weather sensor.
An “intelligent” mechanism reacts to changes in humidity and changes in the atmosphere - during rain, strong wind or snow, the sensor will trigger and the window will close on its own.
It is possible to connect an automation electric drive to a general fire safety system. In case of smoke in the room, the drive will work and the sash will open
The automatic ventilation method has the same disadvantages as the manual method.
Window and wall valve. Overhead and built-in inlets perform the same function - open access to fresh air flows into the room. Varieties of valves differ in their characteristics and installation technology.
Wall models of valves are more productive, it is advisable to use them in spacious rooms. Window storages are suitable for compact rooms
Installation of a wall device is more complicated than installing a supply air duct on a window sash, since it requires drilling a through hole through a structural component of a building. Products for windows are cheaper than wall analogues.
Non-channel devices for the forced flow of air jets:
- Ventilators. In fact, this is the same wall valve only with a built-in fan. The intake of fresh air does not depend on the external parameters of the atmosphere (temperature, pressure), but is determined solely by the performance of the fan.
- Breathers. Unlike ventilators, the installation provides high-quality multi-stage filtration. An additional plus is the availability of climate control. The user sets a comfortable temperature, and the “smart” device automatically heats the air.
- Air conditioners with optional air supply. Multifunctional two-unit split complexes with a mixture of air from the outside are equipped with an air duct connecting both buildings, as well as an air mass filtration system.
The listed devices are mounted without laying an air duct and work to supply air to one room. For a comprehensive restoration of the supply function of ventilation in several rooms at once, channel systems are used.
Air ducts must be taken care of even at the repair stage. Otherwise, you will have to dismantle the finish or create a false box for laying ventilation ducts
Features of ducted supply systems:
- high performance;
- the possibility of heating the air;
- management automation;
- sufficient sound insulation;
- the high cost of component parts;
- complexity of installation.
Duct ventilation is rarely installed in apartments. Priority areas of application: offices, cottages and public facilities.
You will learn how to check the performance of wall and window ventilation valves by reading the following article.
Budget options for restoring air exchange
Wall and window valves do not have a fan. Air inflow occurs due to the difference between street and "home" pressure. A prerequisite for the performance of overhead air inlets is good exhaust ventilation.
Features of different types of window valves
The design of all window climate devices is very simple. A typical valve consists of an air intake, a telescopic channel and an indoor unit.
The air intake is mounted outside the frame. The external unit is equipped with a visor and grille, which prevents insects from getting inside. The telescopic channel crashes into the frame, forming a through slot for unhindered air flow.
The indoor unit is mounted on the side of the room. Some models of air inlets are equipped with a filter and a valve that regulates the throughput of the device
Based on the design and installation method, the following climate devices are distinguished:
- slotted;
- folded;
- waybills.
Slotted models. The capacity of the unit reaches 20 cubic meters per hour - the air mass flows through a micro-hole up to 1.6 cm high and up to 4 cm wide. The device consists of two blocks, which complicates its installation - window frame milling is required .
Folded valves. This is the most affordable and easiest way to ventilate a room. The air flow through the slots in the narthex. The main plus of the models is the ability to install on an operated window without milling a groove.
Additional advantages of rebate models include: low cost, preservation of sound-absorbing and heat-retaining properties of PVC glass and the possibility of automation.
The valve capacity does not exceed 5 cubic meters / h. To ensure a larger volume of air supply, several valves can be installed on one window
Overhead climate products. This option is rarely implemented in domestic conditions due to the complexity of installation - the valve is inserted at the assembly stage of the glass packet. In addition, the product degrade the heat and noise insulation of the window.
Overhead modifications have found their application in production and storage facilities. Productivity of climatic devices is about 100 cubic meters / h.
In the simplest models of window air inlets, the size of the slit, and, consequently, the intensity of the air flow, is manually selected - the position of the valve is regulated. High-tech devices are equipped with humidity and atmospheric vibration sensors.
Wall model: device and installation
Externally, the wall valve resembles a cylindrical flask or a wide pipe, with a diameter of about 10-16 cm.
The plastic duct is equipped with the following elements:
- heat-insulating layer - “sleeve” passes through the entire flask, preventing freezing of the wall and reducing the noise effect from the street;
- filter - located at the outlet of the duct, implements rough air cleaning.
In some models, a sealing (silicone) ring with dampers is placed in front of the filter. The purpose of the part is to equalize the air flow in windy weather.
From the street side, the wall duct is closed with a metal grill and mosquito net, and from the inside - with a decorative cover with an adjusting handle
When choosing a supply device, first of all, the power and “working” temperature of the unit are evaluated. On average, the productivity of a wall-mounted climate product is 40 cubic meters per hour. This value is enough to ventilate a room of 13 sq.m.
The operating temperature range is indicated by the manufacturer on the packaging or in the instrument manual. For severe climatic conditions, special models have been developed that prevent the formation of condensate and the appearance of an ice plug in the channel.
The following photo selection will visually familiarize with the wall valve mounting technology:
Image Gallery
Photo from
Step 1: Drilling a Valve Installation Hole
Step 2: Refine the hole with a drill
Step 3: Drilling a hole
Step 4: Marking for mounting the valve body
Step 5: Install the filter in a fixed housing
Step 7: Installing the Supply Valve Cover
Step 7: Verify System Health
Step 8: Installing the grille from the front
Stage 1. Definition of a place. When choosing a wall, you should consider some of the nuances:
- installation is best done on a supporting structure;
- optimal - “exit” of the valve to the insulated loggia;
- it is better to avoid mounting from the roadway.
Valve manufacturers have indicated recommended and undesired installation areas. When installing, it is important to consider the airflow vector.
In the first version, fresh air, getting into the apartment, warms up and goes down. The second option - the air masses are heated by a heating radiator
Stage 2. Wall preparation and drilling. Mark the space under the through hole on the inner wall and draw the diameter of the valve.
Channel drilling order:
- Perform the initial drilling with a diamond crown to a depth of 10 cm.
- Remove debris and chisel a small notch for stable placement of the drill.
- When drilling, adhere to the outward slope - this position of the duct will prevent rainwater from entering the device.
The work is best done with an assistant who will periodically wet the drilling site. Humidification will reduce dust and protect the tool from overheating.
Stage 3. Installation of valve accessories. Clean the groove from dust and place a heat-insulating “sleeve” in the channel. Install the cylindrical body of the device with screwdriving movements, and fasten the fine-mesh grid on it.
The panel, the ring with dampers and the filter are fixed from the inside of the wall. Finishing stage of assembly - installation of the cover with an adjusting handle
Channelless forced ventilation
Prichochki of this category are considered the best solution to the problems with the supply of fresh air to a high-rise apartment and a private house. They are quite powerful, independent of weather changes, and their installation does not cause special difficulties.
Advanced Wall Valve
Wall-mounted ventilator with the impulse of an air stream is a modernized analogue of a wall inlet valve. The fundamental difference in the design is the presence of a fan, which is injected by an air stream.
The mechanical flow rate is determined by the fan speed. The amount of energy consumed and noise characteristics depend on the selected mode.
The principle of operation of the ventilator:
- Rotating fan blades pressurize street air.
- Passing through the duct, the air masses are cleaned and enter the apartment.
- The exhaust air moves towards the exhaust ducts and is discharged through the ventilation hole.
The degree of purification of the supplied air flow depends on the built-in filtration system. Optimally, if the ventilator is equipped with different types of filters.
A fan ventilator works even with a poorly efficient exhaust system. Forced feed increases air pressure, which positively affects the performance of the hood.
Breezer - compact air handling unit with climate control
The breather is designed to maintain air circulation inside the premises with an area of 10-50 sq.m. The device simultaneously solves several problems: supplying clean air and heating it to the set temperature values.
The main area of application of breathers is residential premises, that is, cottages, private houses and apartments. The device is also in demand in small offices
The breather is a technically sophisticated device with an option for climate control and a control system. Components of the air handling unit:
- Air intake with grille - protects the device from insects and rainwater inside.
- An insulated duct is a sealed duct providing air flow. The heat-insulating liner prevents freezing of the wall and reduces noise.
- Automatic damper - opens the channel for the influx of street air after turning on the device and closes after turning off. The element prevents the leakage of cold air into the apartment.
- The fan is responsible for the amount of intake air from the street.
- The communication unit and control system are the “brains” of the breather, which is responsible for all the working processes of the device.
The compact installation is equipped with a complete filtration system. The cascade of filters implements three degrees of purification.
Coarse filter - removal of medium and large particles (wool, dust, plant pollen). HEPA filter - particle retention of 0.01-0.1 microns in size, including mold spores and bacteria. AK filter - carbon filtration of smoke, odors and industrial emissions
The breather is the optimal solution for creating ventilation in an apartment with filtration, providing up to 80-90% of air mass removal from atmospheric dust. The installation process is quite simple:
Image Gallery
Photo from
Step 1: Marking the ventilation inlet
Step 2: Installing the guides of the drilling machine
Step 3: Fastening the drill with a diamond crown
Step 4: Dust removal with an industrial vacuum cleaner
Step 5: Installing the casing with a drilled hole
Step 6: Mounting the housing with the working part
Step 7: Connect the equipment to power
Step 8: Attaching the External Grille to the Hole
Fresh Air Conditioners
95% of the split systems on sale operate with static air. They continuously recycle the atmosphere of a closed room. Typical air conditioners perform their main task and the room becomes cooler. However, fresh air from their work is not added.
Manufacturers of split systems proposed their own solution to the issue of lack of fresh air and developed air conditioners with a mixture of air from the outside.
Features of the design of the split system with the inflow:
- air intake is carried out through air ducts going from the external unit to the internal one;
- a turbine with a filtration system, which is responsible for supplying and cleaning air, is provided on the street building.
Some models of air handling units are equipped with an oxygen concentrator, and the oxygen level in the room is controlled by special sensors.
An oxygen concentrator passes street air through a membrane membrane separating oxygen molecules from other gaseous substances. As a result, the oxygen concentration increases
The principle of operation of the "split-system with a mixture":
- Fresh air through the suction fan enters the duct to the evaporative (internal) unit.
- Street air flows mixed with room air.
- After filtering and additional processing (cooling, heating), air flows into the apartment.
Despite the good idea of technologists, such models of climate systems are not in great demand. Air conditioners with air inlet work loudly and are not able to provide full ventilation of the apartment. In addition, the cost of advanced equipment is 20% higher than the price of a conventional air conditioner.
Supply duct multi-systems
Duct ventilation is a complex of air ducts laid in all rooms. The heart of the system is the supply air equipment located at the entrance.
The scheme of construction and operation of ventilation is determined by the type of ventilation installation. We outline the features of the two most economical and efficient ways of organizing air supply: ventilation with recovery and the use of VAV units.
The principle of operation of the complex with recovery
The recuperator is a component of the supply and exhaust system. The heat exchanger can significantly reduce energy consumption, ensuring the transfer of heat from the heated exhaust air to the cold incoming flows.
For the functioning of the recuperator, in addition to the supply air duct, installation of exhaust ducts is required, which affects the cost of the system. The efficiency of some heat exchangers reaches 95%
In ventilation systems, two types of heat exchangers are installed: plate and rotary.
Lamellar recuperators. Structurally, they are a cassette installed in the duct. Air flows are "cut" by a block of plates. Warm air passes on one side of the plate, and cold on the other. Due to heat exchange, condensation is formed which must be removed.
Features of plate recuperators:
- fresh supply and exhaust air do not mix;
- probability of freezing in winter;
- in recuperators made of vapor-permeable thin films, condensate does not accumulate.
However, the life of such equipment is limited to ten years.
Rotary recuperators. The principle of heat redistribution is based on the rotation of the drum through which versatile air jets move. Gradually, rotating in a drum set, the exhaust air “shares” the heat with the rotor sector. When the heated portion of the rotor enters the cold supply stream, the air heats up and the rotor cools.
Rotary recuperators are compact in size and highly energy efficient. The disadvantage of this device is the partial mixing of dirty and fresh air. In cold weather, turning off rotary models is undesirable
Details about the device and the principle of operation of air conditioning systems with heat recovery are written in this article, which we advise you to read.
VAV system - ventilation as needed
Variable Air Volume (VAV) installation - an effective ventilation system that provides air intake and heating with minimal energy consumption. The complex allows you to adjust the parameters and ventilation mode for each room separately.
The standard ventilation system supplies air without taking into account the time of day, the purpose of the room and the number of residents. The performance of the VAV-system is selected by the user based on specific operating conditions.
An example of VAV ventilation. Suppose that a complex with a maximum capacity of 300 cubic meters / h serves two rooms: a bedroom and a living room. If in winter there wasn’t enough air heater power to warm the air flow to a comfortable temperature, then in the case of conventional ventilation, the total productivity would have to be reduced. As a result, it would be stuffy in both rooms.
The operation of the VAV-system can be adjusted: during the day to supply air to the living room, and at night - to the bedroom. Each room has a separate ventilation switch
Adjustment of productivity allows to save up to 25-50% of energy in comparison with traditional ventilation.
In addition to reducing electricity bills, the VAV system has other advantages:
- lack of freezing equipment;
- "Mining" is output through the existing ventilation ducts, so there is no need to equip a network of exhaust ducts;
- low cost of operation.
The disadvantage of VAV ventilation is the high price of equipment and difficulties in assembling and adjusting the operability of the complex. Design and installation should be carried out by specialists.
Video # 1. Technology for installing Aereco inlet on an operated window construction:
Video # 2. The principle of functioning of the supply ventilation with filtration by the example of the Tion breather:
Video # 3. The scheme of operation of the VAV ventilation system in different modes:
When choosing a method of organizing air exchange, many parameters are taken into account: the pricing policy of the equipment, the efficiency of the installation, the features of operation under different weather conditions, the presence of options for filtering and heating the air masses.
Among the many units, the optimal balance of cost and quality is demonstrated by breathers specially designed for domestic use in the apartment.
Want to talk about how efficient ventilation works in your house / apartment? Perhaps you yourself improved ventilation by installing a breather or a supply valve on the window sash? Please write comments in the block below, share your impressions, opinions and photos on the topic of the article.