Any household appliances periodically break down, and a gas water heater is no exception. With timely cleaning and compliance with the operating rules, such a device works properly. But if the appliance does not turn on or the flame goes out immediately, serious damage may be detected.
To understand why the geyser goes out, we will understand the features of its structure and functioning. Also in this article we will consider the popular reasons for the fading of the column and ways to restore its performance. The material we have supplemented with visual photos and informative videos.
The device and principle of operation of the column
Inside the column, there are two main elements: a gas burner and a heat exchanger that looks like a long narrow pipe, usually made of copper, rolled up by a snake or spiral. Cold water flows from the water supply to the coil, heats up above the burner and leaves the device when it is already hot.
Of course, everything is not so simple, since a number of important components, such as:
- ignition device or igniter;
- water-gas unit;
- solenoid valve with a set of sensors.
The ignition device often looks like a so-called standby burner: a small tongue of flame that burns constantly. In the electronic version of this unit, immediately before the column is turned on, a spark arises, which ignites the igniter. This is a more modern version, which allows even some gas savings.
It is necessary to start repairing the gas column by studying the design of the device, the location of the main components, as well as the order of their functioning
To obtain a spark, a piezoelectric element is most often used, which can also be started manually. In the models of past years, such amenities are not provided: the ignitor is lit with an ordinary match. In order for the gas to turn on automatically, a water-gas unit is needed when starting up the water. It consists of a membrane that is mounted in the water supply, and a valve in the gas path.
When the tap is opened, water begins to move, the membrane changes its position under the influence of flow and transmits a signal to the valve. It opens and starts the flow of gas to the burner, which is ignited. When the water is turned off, the membrane returns to its original position, the valve blocks the gas flow, the burner goes out.
If no gas enters the main burner of the column, it is most likely blocked by one of the safety elements that responded to some malfunction
Thanks to the gas-water unit, it is not necessary to manually open the gas each time the water is turned on. The solenoid valve also controls the gas supply in accordance with the readings of various sensors that detect the presence of flame, draft, dangerous overheating, etc.
This node is necessary to increase system security. Sensors respond to system malfunctions, and the valve shuts off gas supply if serious problems arise in the operation of the device.
In addition to sensors, a thermocouple is connected to the valve. This element responds to the presence or absence of a standby burner flame. If there is no fire, the gas entering the column will not ignite, but will accumulate, which is very dangerous.
If the column needs to be disassembled, first you need to determine the places for connecting water and gas in order to block these pipes with appropriate valves
Reasons for column fading
Any of the nodes described above may cause column attenuation. The flame goes out if the security system detects a violation of normal operation. To start the device, you will need to identify and eliminate the cause of such a violation.
Here are the most common options for possible problems:
- there is no draft in the chimney;
- the main burner has gone out;
- there is a dangerous increase in water temperature in the heat exchanger;
- individual elements are worn out and require replacement.
If the column does not give a flame, first you need to make sure that its operating conditions are not violated, and check the manufacturer's warranty terms. The necessary information is contained in the technical passport of the product and the manual for its use.
Reason # 1 - lack of draft in the chimney
Traction testing is the easiest way to diagnose the condition of the device. You just need to bring a strip of thin paper or a flame of a lighter, matches, etc. to the viewing hole of the column. But if there is even a slight suspicion of a gas leak, it is better to refuse to use open flame.
Reverse draft is a dangerous phenomenon, it can blow out the flame of the standby burner, after which the gas flow to the device will be stopped
If the paper or flame pulls inward, everything is in order, traction is available. The absence of changes in their position indicates the absence of traction, and the deviation in the opposite direction indicates that there is a reverse traction.
to verify the causes of the problem, you need to disconnect the column and check the draft in the same way only in the chimney. After that, it will become clear whether there are malfunctions in the chimney duct or inside the column too.
When the chimney structure is in order, the heat exchanger becomes the “culprit” of the lack of draft, or rather, the soot particles that clog it, which impede normal air exchange. It is necessary to remove the protective cover from the column and clean the heat exchanger with a hard brush.
Improper installation of the chimney of the gas column can lead to a decrease or lack of draft, rapid clogging with soot and soot, as well as other dangerous problems
If the chimney is dirty, it remains just to clean it and reconnect it to the device. In the absence of a positive reaction, make sure that the chimney structure is assembled correctly from suitable materials. Sometimes the cause of lack of traction can be flaws in the installation of this part of the system.
Often problems of this type arise for external reasons, such as the lack of proper ventilation of the room. Plastic windows and a tightly closed door practically seal the room in which the speaker is located. There is no fresh air flow, so there is no movement in the chimney.
It does not hurt to check the ventilation system in the whole house or apartment.
Traction testing is an important safety feature when using a gas column. This procedure should be carried out regularly, without waiting for problems to appear.
You need to make sure that a sufficient amount of fresh air enters the room. If it is not possible to naturally organize ventilation, you can install a supply valve on the windows or on the wall.
Then you need to make sure that the air flows not only enter the house, but also move freely throughout the premises. To do this, it is necessary to install ventilation grilles on the doors or make a small clearance below.
Reason # 2 - regular burner attenuation
The absence of a standby burner flame is detected by the sensor, after which the gas supply is immediately shut off. Such a situation may occur if a small light was hit by a strong gust of wind. There is no need to draft indoors while working, especially if it is very windy outside.
Strong air currents can penetrate not only through windows and doors, but also through the chimney. The result may be the same - the burner goes out, the automation blocks the gas flow.
To restore the normal operation of the device, turn off the column, check the status of the standby burner (a flame tongue should appear here), and turn on the device again.
Reason # 3 - significant overheating of water
This occurs when the pressure head of the water flow passing through the heat exchanger decreases, and the heating intensity remains unchanged. In some cases, even boiling water can be observed, which is dangerous for the integrity of the device.
Pressure decreases when cold water is opened to dilute the flow to a comfortable temperature, and cold water displaces hot water. It is better to regulate the heating using the column settings.
Another reason for the occurrence of this phenomenon is a calcareous sediment accumulated inside a narrow heat exchanger pipe. To restore normal pressure, you need to regularly descale the device, and make sure that the water is not too hot. For domestic needs, it is enough to warm the water to 45-50 degrees.
This mode helps to reduce the formation of solid sediment. If the water in the system is too hard, and you often have to clean the heat exchanger, it makes sense to think about installing a special filter that will remove it from the salt stream. Cleaning the heat exchanger is carried out using special means or household chemicals: soda, vinegar, etc.
You will have to remove the protective cover from the column, as well as block the gas and water. Then the heat exchanger is disconnected from the water supply and dismantled. Inside the pipe of the coil, pour the cleaning composition and leave for a while. After that, the heat exchanger is washed, installed in place and the column is reassembled.
There is an elastic membrane inside the water-gas unit, which wears out over time. In this case, it needs to be replaced, although simple washing sometimes helps.
A mesh filter installed at the inlet of tap water into the heat exchanger is periodically clogged with contaminants. It also needs to be cleaned. To remove common dirt, just rinse the net in water, but sometimes you have to use chemicals. If damage is found on the filter, it is best to replace it immediately.
Reason # 4 - insufficient water pressure
The lack of a normal water pressure in the system and without overheating can cause the valve to block the gas flow and the burner will go out.
In this situation, you should check the condition of the water supply system, perhaps you just need to install a circulation pump. Even when buying a column, you should ask about the minimum pressure values for a particular model.
To get a spark and ignite the standby burner, on most modern models you need to press the electric or piezo ignition button. If the flame immediately extinguishes, check the condition of the igniter.
Reason # 5 - lack of timely maintenance
Following the manufacturer's recommendations, clean the column regularly. Untimely maintenance does not improve the situation. Consider the main problems that arise for this reason.
Dead batteries
If the column provides for electric ignition, it is carried out using batteries. Dead batteries must be replaced and the problem will be resolved.
And when a piezoelectric element with a turbine is used to obtain a spark, it will not start when the water pressure is weak, this point will need to be taken into account.
If a spark does not form in the igniter, immediately check and replace the batteries, as well as clean the contacts if they are oxidized.
Significant clogging of the igniter
The lack of an on-site burner flame often occurs when the igniter is clogged. Gas simply does not flow in enough to ignite the burner. The igniter must be cleaned with metal wire so that the column starts working.
It is better to clean in advance, without waiting for the hole to clog. Clogs accumulate gradually.
If the ignitor in the gas column is clogged, the burner does not receive enough gas to make a flame tongue, you will have to perform a cleaning
If the flame tongue has noticeably decreased, it's time to check the condition of the igniter. Another sign of the appearance of such a problem is cotton, which is heard when the burner is turned on. A weak flame is not able to immediately ignite the gas entering the device. It gradually accumulates and lights up with a pop that resembles a small explosion.
Membrane contamination or deterioration
As mentioned earlier, there is a membrane in the water-gas unit. This is a polymer element, which when in constant contact with water gradually loses its elasticity. Sometimes cracks even appear on it, limescale deposits, etc. The membrane ceases to respond to the flow of water, as a result, gas does not enter the burner.
It is necessary to disassemble the gas-water unit, remove the worn element and replace it with a new membrane.
If, upon examination, it turns out that the contaminants are not too large, and the element remains elastic, you can simply rinse the membrane and install it in its original place.
In modern models with a lot of electronics, the control board may burn out, after which the speaker, of course, will not light up.
Coarse filter clogged
The reason for such a breakdown is the poor quality of power supply, for which foreign devices are not designed. In addition, some electronically controlled models should not be turned off at night, they should be turned on constantly. To solve the problem of voltage drops in the network, you can use a stabilizer.
Clogging of the coarse filter can lead to a dangerous decrease in the pressure of water entering the gas column. This element must be regularly cleaned and replaced if necessary.
Typical problems for individual models
Even the columns of well-known companies can break down over time for a variety of reasons. During operation, device owners noticed breakdowns that most often occur with specific models.
Junkers Bosch Thermocouple Problems
For example, the weak point of the Bosch Junkers WR 13-P device is a thermocouple.
Two to three years after the start of operation, it ceases to respond normally to heat from the standby burner. As a result, the igniter flame constantly extinguishes, over time, it simply ceases to light up normally.
Sometimes it helps to clean the thermocouple with fine sandpaper, but when this method ceases to bring the desired effect, the element will have to be replaced.
In some models of geysers, a thermocouple breaks down over time, which is easy to replace with a new element
The displacement of the pilot tube, which is not fixed too firmly in similar models, can also lead to similar problems. The tube can be moved accidentally, even just hitting it with a match during ignition. Between the nozzle of the gas tube and the burner there is a gap through which air enters.
When displaced, this gap decreases, the air required for normal ignition becomes insufficient. The flame tongue does not reach the thermocouple, it does not heat up, gas does not enter the main burner. If you restore the normal position of the tube, the column will again work properly.
Practical recommendations for cleaning and repairing breakdowns in the JUNKERS column:
Oxidation of contacts at columns Vector
For the “Vector” columns, the oxidation of contacts in the power supply is considered a typical problem. If this is the case, then replacing the dead batteries with new elements will not give the desired result, the spark will not appear until the contacts are cleaned. Sometimes in such columns souring of the microswitch rod on the water valve is observed.
If the column sizzles or whistles during operation, it is possible that the fastenings of the coil tubes are loosened, they need to be checked and sealed
After cleaning, normal operation is usually restored.If a characteristic whistle appears shortly after turning on the column, you need to check the condition of the gas outlet pipe connections; perhaps they need to be re-sealed.
Problems with the stock in the Neva models
In the columns of the brand "Neva" sometimes sticking of the rod in the gas valve is observed. As a result, this element stops normal operation.
To eliminate such a malfunction, it is necessary to remove and disassemble the gas-water unit, and then move the rod with an ordinary screwdriver. If the part is not amenable to mechanical stress, the element should be completely replaced.
This video demonstrates troubleshooting for the NEVA column:
You can look for the causes and solutions to the column attenuation problem here:
Column attenuation is a symptom of an internal malfunction or violation of the instrument's operating conditions. It is necessary to find out the cause of the problem correctly, after which a significant part of the described failures can be eliminated independently. But to solve complex problems you will have to contact a service center.
Do you have any questions while searching for the cause of the attenuation of the column? Ask them under this article - our experts and site visitors will try to help you.
Or maybe you want to tell other users about the problems that occurred with your column during operation, and their successful solution? Share your experience, leave recommendations in the block below.